Bruce's Coil
This is the coil I built for my brother.
TCBOR/RQ Static Gap Construction
The 3/4" copper electrodes have been tapped and the fan mount completed.
Drilling the holes for the electrodes and milling slots for air to escape.
The unit is complete and ready to go!
Completed Secondary
Secondary Measurements and Calculations
Scope, signal generator, frequency counter, and antenna set up to measure the unloaded resonant frequency of the secondary coil. Secondary is being base driven from signal generator and the signal is being picked up via a 1-foot antenna hanging from a 10x probe.
The unloaded Frequency measured 1.018mhz.
The loaded frequency (with a 10.5" x 4" Toroid) measures 582khz.
Secondary Specifications
Form Diameter
2.37"
Form Type
2" Sched 40 PVC
Winding Length
16.22"
Wire Gauge
24 awg (.022"od)
Turns Per Inch (TPI)
45
Wire Length
714'
Under Coating
Spray on Electrical Varnish
Top Coating
Pour on Epoxy (two light coats)
Calculated
Inductance (Lsec)
4.1 mH
Self Capacitance (Cself)
6.0 pf
Resonant Frequency (unloaded)
1,014 khz
Resonant Frequency (loaded)
527 khz (w 10.5"x4" toroid)
Measured
Inductance (Lsec)
4.1 mH
DC Resistance
12.0 ohms
Resonant Frequency (unloaded)
1,018 khz
Resonant Frequency (loaded)
582 khz (w 10.5"x4" toroid)
Bruce 2.xlsExcel spreadsheet · 133 KB